A review of closed-loop algorithms for glycemic control in the treatment of type 1 diabetes

Joseph El Youssef, Jessica Castle, W. Kenneth Ward

Research output: Contribution to journalReview articlepeer-review

50 Scopus citations

Abstract

With the discovery of insulin came a deeper understanding of therapeutic options for one of the most devastating chronic diseases of the modern era, diabetes mellitus. The use of insulin in the treatment of diabetes, especially in those with severe insulin deficiency (type 1 diabetes), with multiple injections or continuous subcutaneous infusion, has been largely successful, but the risk for short term and long term complications remains substantial. Insulin treatment decisions are based on the patient's knowledge of meal size, exercise plans and the intermittent knowledge of blood glucose values. As such, these are open loop methods that require human input. The idea of closed loop control of diabetes treatment is quite different: automated control of a device that delivers insulin (and possibly glucagon or other medications) and is based on continuous or very frequent glucose measurements. Closed loop insulin control for type 1 diabetes is not new but is far from optimized. The goal of such a system is to avoid short-term complications (hypoglycemia) and long-term complications (diseases of the eyes, kidneys, nerves and cardiovascular system) by mimicking the normal insulin secretion pattern of the pancreatic beta cell. A control system for automated diabetes treatment consists of three major components, (1) a glucose sensing device that serves as the afferent limb of the system; (2) an automated control unit that uses algorithms which acquires sensor input and generates treatment outputs; and (3) a drug delivery device (primarily for delivery of insulin), which serves as the system's efferent limb. There are several major issues that highlight the difficulty of interacting with the complex unknowns of the biological world. For example, development of accurate continuous glucose monitors is crucial; the state of the art in 2009 is that such devices sometimes experience drift and are intended only to supplement information received from standard intermittent blood glucose data. In addition, it is important to acknowledge that an " automated" closed loop pancreas cannot approach the complexity of the normal human endocrine pancreas, which takes continuous data from substrates, hormones, paracrine compounds and autonomic neural inputs, and in response, secretes four hormones. Another major issue is the substantial absorption/action delay of insulin given by the subcutaneous route. Because of this delay, some researchers have recently given a portion of the mealrelated insulin in an open loop manner before the meal and found this hybrid approach to be superior to closed loop control. Proportional-Integral-Derivative (PID) systems adapted from the industrial sector utilize control algorithms that alter output based on proportional (difference between actual and target levels), derivative (rate of change) and integral (time-related summative) errors in glucose. These algorithms have proven to be very promising in limited clinical trials. Related algorithms include a " fading memory" system that combines the proportionalderivative components of a classic PID system with time-relating decay of input signals that allow greater emphasis on more recent glucose values, a characteristic noted in mammalian beta-cells. Model Predictive Control (MPC) systems are highly adaptive methods that utilize mathematical models based on observations of biological behavior patterns using system identification and are now undergoing testing in humans. The application of further mathematical models, such as fuzzy control and artificial neural networks, are also promising, but are largely clinically untested. In summary, the prospects for closed loop control of glycemia in persons with diabetes have improved considerably. Major limitations include the delayed absorption/action of subcutaneous insulin and the imperfect stability of currently-available continuous glucose sensors. The potential for improved glycemic control in persons with diabetes brings with it the potential for reduction in the frequency of acute and chronic complications of diabetes.

Original languageEnglish (US)
Pages (from-to)518-532
Number of pages15
JournalAlgorithms
Volume2
Issue number1
DOIs
StatePublished - Mar 2009

Keywords

  • Algorithm
  • Closed loop
  • Diabetes
  • Sensor

ASJC Scopus subject areas

  • Theoretical Computer Science
  • Numerical Analysis
  • Computational Theory and Mathematics
  • Computational Mathematics

Fingerprint

Dive into the research topics of 'A review of closed-loop algorithms for glycemic control in the treatment of type 1 diabetes'. Together they form a unique fingerprint.

Cite this