A reversible cause of 'end-stage renal disease': Discrepant findings in serial duplex ultrasonograms in a suspected occlusion of a renal arterial bypass graft

Ashvin Baru, Eric Scott Kerns, David Cohen

Research output: Contribution to journalArticle

Abstract

Duplex ultrasonography may be inaccurate due to a number of variables in operator and patient characteristics. We describe a 40-year-old woman who presented with acute kidney injury after prior complex abdominal aortic surgery that had left her with an essentially solitary functional kidney. On the basis of normal Doppler findings, she was started on dialysis. Owing to high clinical suspicion and a failure of renal function to return, a second Doppler study was performed 3 weeks after the first, revealing the characteristic tardus-parvus waveform of renal artery stenosis. The patient underwent urgent renal arterial angioplasty and stent placement. She experienced an immediate increase in urinary output, required no further dialysis, and the creatinine improved to 1.7 mg/dL (her prior renal baseline). The case illustrates an important complication of abdominal aortic aneurysm repair, draws attention to a potential source of error in the Doppler measurement, and underscores the limitations of duplex ultrasonography for excluding renal artery stenosis in the presence of high pretest probability.

Original languageEnglish (US)
JournalBMJ Case Reports
DOIs
StatePublished - Dec 4 2013

Fingerprint

Chronic Kidney Failure
Renal Artery Obstruction
Transplants
Kidney
Dialysis
Ultrasonography
Abdominal Aortic Aneurysm
Angioplasty
Acute Kidney Injury
Stents
Renal Insufficiency
Creatinine
Research Design

ASJC Scopus subject areas

  • Medicine(all)

Cite this

@article{0d3c1b6f36f64e1dadabd114c9bfec3a,
title = "A reversible cause of 'end-stage renal disease': Discrepant findings in serial duplex ultrasonograms in a suspected occlusion of a renal arterial bypass graft",
abstract = "Duplex ultrasonography may be inaccurate due to a number of variables in operator and patient characteristics. We describe a 40-year-old woman who presented with acute kidney injury after prior complex abdominal aortic surgery that had left her with an essentially solitary functional kidney. On the basis of normal Doppler findings, she was started on dialysis. Owing to high clinical suspicion and a failure of renal function to return, a second Doppler study was performed 3 weeks after the first, revealing the characteristic tardus-parvus waveform of renal artery stenosis. The patient underwent urgent renal arterial angioplasty and stent placement. She experienced an immediate increase in urinary output, required no further dialysis, and the creatinine improved to 1.7 mg/dL (her prior renal baseline). The case illustrates an important complication of abdominal aortic aneurysm repair, draws attention to a potential source of error in the Doppler measurement, and underscores the limitations of duplex ultrasonography for excluding renal artery stenosis in the presence of high pretest probability.",
author = "Ashvin Baru and Kerns, {Eric Scott} and David Cohen",
year = "2013",
month = "12",
day = "4",
doi = "10.1136/bcr-2013-201600",
language = "English (US)",
journal = "BMJ Case Reports",
issn = "1757-790X",
publisher = "BMJ Publishing Group",

}

TY - JOUR

T1 - A reversible cause of 'end-stage renal disease'

T2 - Discrepant findings in serial duplex ultrasonograms in a suspected occlusion of a renal arterial bypass graft

AU - Baru, Ashvin

AU - Kerns, Eric Scott

AU - Cohen, David

PY - 2013/12/4

Y1 - 2013/12/4

N2 - Duplex ultrasonography may be inaccurate due to a number of variables in operator and patient characteristics. We describe a 40-year-old woman who presented with acute kidney injury after prior complex abdominal aortic surgery that had left her with an essentially solitary functional kidney. On the basis of normal Doppler findings, she was started on dialysis. Owing to high clinical suspicion and a failure of renal function to return, a second Doppler study was performed 3 weeks after the first, revealing the characteristic tardus-parvus waveform of renal artery stenosis. The patient underwent urgent renal arterial angioplasty and stent placement. She experienced an immediate increase in urinary output, required no further dialysis, and the creatinine improved to 1.7 mg/dL (her prior renal baseline). The case illustrates an important complication of abdominal aortic aneurysm repair, draws attention to a potential source of error in the Doppler measurement, and underscores the limitations of duplex ultrasonography for excluding renal artery stenosis in the presence of high pretest probability.

AB - Duplex ultrasonography may be inaccurate due to a number of variables in operator and patient characteristics. We describe a 40-year-old woman who presented with acute kidney injury after prior complex abdominal aortic surgery that had left her with an essentially solitary functional kidney. On the basis of normal Doppler findings, she was started on dialysis. Owing to high clinical suspicion and a failure of renal function to return, a second Doppler study was performed 3 weeks after the first, revealing the characteristic tardus-parvus waveform of renal artery stenosis. The patient underwent urgent renal arterial angioplasty and stent placement. She experienced an immediate increase in urinary output, required no further dialysis, and the creatinine improved to 1.7 mg/dL (her prior renal baseline). The case illustrates an important complication of abdominal aortic aneurysm repair, draws attention to a potential source of error in the Doppler measurement, and underscores the limitations of duplex ultrasonography for excluding renal artery stenosis in the presence of high pretest probability.

UR - http://www.scopus.com/inward/record.url?scp=84890282320&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890282320&partnerID=8YFLogxK

U2 - 10.1136/bcr-2013-201600

DO - 10.1136/bcr-2013-201600

M3 - Article

AN - SCOPUS:84890282320

JO - BMJ Case Reports

JF - BMJ Case Reports