TY - JOUR
T1 - A rapid, automated enzymatic fluorometric assay for determination of D- arabinitol in serum
AU - Yeo, Siew Fah
AU - Zhang, Yeyan
AU - Schafer, David
AU - Campbell, Sheldon
AU - Wong, Brian
PY - 2000
Y1 - 2000
N2 - A rapid enzymatic fluorometric assay for measuring D-arabinitol in serum was developed using recombinant D-arabinitol dehydrogenase from Candida albicans (rArDH). rArDH was produced in Escherichia coli and purified by dye- ligand affinity chromatography. rArDH was highly specific for D-arabinitol, cross-reacting only with xylitol (4.9%) among all polyols tested. A Cobas Fara II centrifugal autoanalyzer (Roche) was used to measure NADH fluorometrically when rArDH and NAD were added to serum extracts, and D- arabinitol concentrations were calculated from standard curves derived from pooled human serum containing known amounts of D-arabinitol. The method was precise (mean intra-assay coefficients of variation [CVs], 0.8%, and mean inter-assay CVs, 1.6%) and rapid (3.5 min per assay) and showed excellent recovery of added D-arabinitol in serum (mean recovery rate, 101%). The mean and median D-arabinitol/creatinine ratios were 2.74 and 2.23 μM/mg/dl, respectively, for the 11 patients with candidemia compared to 1.14 and 1.23 μM/mg/dl, respectively, for 10 healthy controls (P < 0.01). These results confirm earlier studies showing that serum D-arabinitol measurement may help to promptly diagnose invasive candidiasis. The technique shows a significant improvement in terms of accuracy, cost, simplicity, specificity, and speed compared with gas chromatography, mass spectrometry, and earlier enzymatic assays.
AB - A rapid enzymatic fluorometric assay for measuring D-arabinitol in serum was developed using recombinant D-arabinitol dehydrogenase from Candida albicans (rArDH). rArDH was produced in Escherichia coli and purified by dye- ligand affinity chromatography. rArDH was highly specific for D-arabinitol, cross-reacting only with xylitol (4.9%) among all polyols tested. A Cobas Fara II centrifugal autoanalyzer (Roche) was used to measure NADH fluorometrically when rArDH and NAD were added to serum extracts, and D- arabinitol concentrations were calculated from standard curves derived from pooled human serum containing known amounts of D-arabinitol. The method was precise (mean intra-assay coefficients of variation [CVs], 0.8%, and mean inter-assay CVs, 1.6%) and rapid (3.5 min per assay) and showed excellent recovery of added D-arabinitol in serum (mean recovery rate, 101%). The mean and median D-arabinitol/creatinine ratios were 2.74 and 2.23 μM/mg/dl, respectively, for the 11 patients with candidemia compared to 1.14 and 1.23 μM/mg/dl, respectively, for 10 healthy controls (P < 0.01). These results confirm earlier studies showing that serum D-arabinitol measurement may help to promptly diagnose invasive candidiasis. The technique shows a significant improvement in terms of accuracy, cost, simplicity, specificity, and speed compared with gas chromatography, mass spectrometry, and earlier enzymatic assays.
UR - http://www.scopus.com/inward/record.url?scp=0342264687&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0342264687&partnerID=8YFLogxK
U2 - 10.1128/jcm.38.4.1439-1443.2000
DO - 10.1128/jcm.38.4.1439-1443.2000
M3 - Article
C2 - 10747122
AN - SCOPUS:0342264687
SN - 0095-1137
VL - 38
SP - 1439
EP - 1443
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
IS - 4
ER -