TY - JOUR
T1 - A greater analgesia, sedation, delirium order set quality score is associated with a decreased duration of mechanical ventilation in cardiovascular surgery patients
AU - Dale, Christopher R.
AU - Bryson, Christopher L.
AU - Fan, Vincent S.
AU - Maynard, Charles
AU - Yanez, N. David
AU - Treggiari, Miriam M.
PY - 2013/11
Y1 - 2013/11
N2 - OBJECTIVE: Protocols and order sets for the delivery of analgesia, sedation, and delirium care of the critically ill, mechanically ventilated patient have been shown to improve outcomes but are not uniform in hospitals across geographic areas. The extent to which greater order set quality is associated with improved patient outcomes is not known. We hypothesized that cardiac surgery patients cared for at hospitals with a greater analgesia, sedation, and delirium order set quality score (more guideline-concordant order sets) would have a shorter average duration of mechanical ventilation. DESIGN: Retrospective cohort study. SETTING: All Washington State non-federal hospitals providing cardiac surgery. PATIENTS: All mechanically ventilated cardiac surgery patients from January 1, 2008, until September 30, 2011. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We created a multivariable linear regression model to assess the relationship between a hospital's pain, agitation and delirium order set quality, as assessed by an expert-validated order set quality score, and the average duration of mechanical ventilation of its cardiac surgery patients, independent of other hospital and patient factors. A total of 19,561 patients underwent cardiac surgery at 16 Washington state hospitals during the study period. The order set quality scores ranged from 4 to 19 with a mean of 11.8 ± 4.5. The mean duration of mechanical ventilation was 27.0 ± 196.6 hours. In the multivariable model, independent of other patient and hospital factors, a 1-point increase in the order set quality score was associated with a 3.3 ± 0.9 hour (p < 0.01) decrease in average duration of mechanical ventilation. CONCLUSIONS: Cardiac surgery hospitals with more guideline-adherent analgesia, sedation, and delirium order sets have patients with shorter mean durations of mechanical ventilation than hospitals with lower order set quality scores.
AB - OBJECTIVE: Protocols and order sets for the delivery of analgesia, sedation, and delirium care of the critically ill, mechanically ventilated patient have been shown to improve outcomes but are not uniform in hospitals across geographic areas. The extent to which greater order set quality is associated with improved patient outcomes is not known. We hypothesized that cardiac surgery patients cared for at hospitals with a greater analgesia, sedation, and delirium order set quality score (more guideline-concordant order sets) would have a shorter average duration of mechanical ventilation. DESIGN: Retrospective cohort study. SETTING: All Washington State non-federal hospitals providing cardiac surgery. PATIENTS: All mechanically ventilated cardiac surgery patients from January 1, 2008, until September 30, 2011. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We created a multivariable linear regression model to assess the relationship between a hospital's pain, agitation and delirium order set quality, as assessed by an expert-validated order set quality score, and the average duration of mechanical ventilation of its cardiac surgery patients, independent of other hospital and patient factors. A total of 19,561 patients underwent cardiac surgery at 16 Washington state hospitals during the study period. The order set quality scores ranged from 4 to 19 with a mean of 11.8 ± 4.5. The mean duration of mechanical ventilation was 27.0 ± 196.6 hours. In the multivariable model, independent of other patient and hospital factors, a 1-point increase in the order set quality score was associated with a 3.3 ± 0.9 hour (p < 0.01) decrease in average duration of mechanical ventilation. CONCLUSIONS: Cardiac surgery hospitals with more guideline-adherent analgesia, sedation, and delirium order sets have patients with shorter mean durations of mechanical ventilation than hospitals with lower order set quality scores.
KW - Cardiac surgery
KW - Intensive care
KW - Mechanical ventilation
KW - Order set
KW - Outcomes
KW - Sedation
UR - http://www.scopus.com/inward/record.url?scp=84887048638&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84887048638&partnerID=8YFLogxK
U2 - 10.1097/CCM.0b013e31829a6ee7
DO - 10.1097/CCM.0b013e31829a6ee7
M3 - Article
C2 - 23989171
AN - SCOPUS:84887048638
SN - 0090-3493
VL - 41
SP - 2610
EP - 2617
JO - Critical Care Medicine
JF - Critical Care Medicine
IS - 11
ER -